| Model |
6605 |
6610 |
6620 |
6640 |
| INPUT |
| Phase |
1 Phase |
| Voltage |
110/220Vac±10% |
| Frequency |
47-63Hz |
| OUTPUT |
| AC |
| Power rating |
500VA |
1000VA |
2000VA |
4000VA |
| Max. Current (r.m.s)*1 |
0-150V |
4.6A |
9.2A |
18.4A |
36.8A |
| 0-300V |
2.3A |
4.6A |
9.2A |
18.4A |
| Max. Current(peak) |
0-150V |
13.8A |
27.6A |
55.2A |
110.4A |
| 0-300V |
6.9A |
13.8A |
27.6A |
55.2A |
| Phase |
1Phase / 2W |
| Total Harmonic Distortation (T.H.D) |
<0.5% at 40 - 100Hz , <1% at 101-500Hz (Resistive Load) |
| Crest Factor |
>= 3 |
| Line Regulation |
± 0.1V
|
| Load Regulation |
±(0.5% of output +0.5V) at Resistive Load |
| Response Time |
<400µS |
| SETTING |
| Voltage |
Range |
0-300V, 150V/300V Auto Range |
| Resolution |
0.1V |
| Accuracy |
±(1% of setting + 2counts) |
| Frequency |
Range |
40-500Hz Full Range Adjust |
| Resolution |
0.1Hz at 40.0-99.9Hz , 1Hz at 100-500Hz |
| Accuracy |
±0.03% of setting |
Starting& Ending
Phase Angle |
Range |
0-360° |
| Resolution |
1° |
| Accuracy |
±1°(45 - 65HZ) |
| DC(Optioin) |
| MAX. Power |
250W |
500W |
1KW |
2KW |
| Max. Current |
0-200V |
2.3A |
4.6A |
9.2A |
18.4A |
| 0-400V |
1.15A |
2.3A |
4.6A |
9.2A |
| SETTING |
| Voltage |
Range |
0-200V / 0-400V Selectable |
| Resolution |
0.1V |
| Accuracy |
±(1% of setting + 2counts) |
| Ripple and Noise (RMS) |
Range : 0-200V <250mV
Range : 0-400V <400mV |
Range : 0-200V<350mV
Range : 0-400V<550mV |
| Ripple and Noise (p-p) |
<2Vp-p |
<3.0Vp-p |
| MEASUREMENT |
| Voltage (AC & DC) |
Range |
0.0-400.0V |
| Resolution |
0.1V |
| Accuracy |
±(1% of reading + 2counts) |
| Frequency |
Range |
0.0-500.0Hz |
| Resolution |
0.1Hz |
| Accuracy |
±0.1Hz |
| Current (rms) (AC & DC) |
Range |
L |
0.005A - 0.600A |
0.005A - 1.200A |
0.005A - 2.400A |
- |
| H |
0.50A -6.50A |
1.00A -13.00A |
2.00A -26.00A |
0.00 - 52.00A |
| Resolution |
L |
0.001A |
| H |
0.01A |
| Accuracy |
L |
±(1% of reading +5counts) |
| H |
±(1% of reading +5counts) |
| Current(peak) |
Range |
0.0 - 19.0A |
0.0 - 76.0A |
0.0 - 152.0A |
- |
| Resolution |
0.1A |
| Accuracy |
±(1% of reading + 5counts) |
| Power |
Range |
L |
0.0W - 60.0W |
0.0W - 120.0W |
0.0W - 240.0W |
- |
| H |
50W -650W |
100W -1300W |
200W -2600W |
0 - 5200W |
| Resolution |
L |
0.1W |
| H |
1W |
| Accuracy |
L |
±(2% of reading +5counts) |
| H |
±(2% of reading +2counts) |
| Power Factor |
Range |
0.000-1.000 |
| Resolution |
0.001 |
| Accuracy |
W / VA ,Calculated and displayed to three significant digits |
| GENERAL |
| Remote Input Signal Interface(Option) |
Test, Reset, Recall memory 1 through 7 |
| Remote Output Signal |
Pass, Fail ,Test-in Process |
| Memory |
50 memories, 9 steps/memory |
| Sync Output Signal |
DC Level 5V |
| Timer |
0=Continuous, 0.5-999.9 (Unit: sec, minute, hour selectable) |
| Alarm Volume Setting |
Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
| Graphic Display |
240 x 64 dot resolution Monographic LCD /Contrast 9 Levels 1-9 |
| Auto loop cycle |
0=Continuous, OFF, 2~9999 |
| Over Current Fold Back |
On/Off , Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value. |
| High / Low Limit Protection |
Arms, Apeak, P, PF |
| Protection |
OCP, OVP, OPP, OTP |
| Efficiency |
≥80%(at Full Load ) |
| Interface (Option) |
GPIB / RS232, PLC Remote Input Card |
| Operation Environment |
0-40˚C/20-80%RH |
| Dimension(WxHxD) mm |
430 x 89 x 400 |
430 x 89 x 400 |
430 x 89 x 500 |
430 x 222 x 500 |
| Net Weight |
16.5Kg |
18.2Kg |
30Kg |
65Kg |